← All use cases

Use case · Brussels, Belgium

An in-house AI assistant inside the patient record

Cliniques universitaires Saint-Luc built its own large language model assistant inside Epic, piloted it with 28 physicians, then opened it hospital-wide to more than 1,000 users.

Built in-houseClinical documentationRAG / knowledgeEpic · SMART on FHIROn-premisesIn production
How this case was documented: from published sources, mainly the team's own paper (Griot, Vanderdonckt, Yuksel, PLOS Digital Health, 2025). It has not yet been reviewed by the Saint-Luc team; we will update it with their input.
28physicians in a one-month pilot, 9 specialties
64%of pilot physicians used it daily
1,028users after five months hospital-wide
14,910conversations in those five months

01The problem

Physicians lose time finding and piecing together information scattered across the record. Preparing a consultation takes emergency physicians at Saint-Luc about 20 minutes per patient, and the literature reports some doctors spending over half their time in the record.

  • The same information is documented twice, in structured fields and in notes.
  • Relevant data sits in many places: hospital documents, regional network documents, internal procedures and the literature.
  • In early workshops, physicians' most requested use cases were all about faster access to information.

02The solution

Saint-Luc built a single chat assistant inside Epic instead of buying a vendor tool. It summarises the patient's chart, answers targeted questions and drafts note sections, and every answer lists the sources it used.

  • Built, not bought. The hospital's stated strategy is to host medical AI on site, because vendor services did not allow the customisation and validation the team needed.
  • What it reads: hospital clinical documents and structured data (allergies, conditions, medications), documents from the Brussels regional health network (RSB), internal procedures, and a curated local copy of the medical literature.
  • Interface: a familiar chat, based on the open-source OpenWebUI and simplified for clinicians. Users can choose sources, switch between fast and reasoning modes, and see which documents were retrieved.
  • Model: Qwen3-235B, run on the hospital's own server with 8 NVIDIA H200 GPUs.
  • Role: non-interventional and optional. It only reads the record; physicians remain responsible for decisions.

03Integration & governance

The assistant opens inside Epic for the current patient and can see only what the logged-in user is already allowed to see. Governance was set up with medical leadership, legal, cybersecurity and clinicians before go-live.

AreaWhat Saint-Luc did
EHR integrationLaunched from Epic via SMART on FHIR; the access token is scoped to the user, the patient and the app. Data and documents come through FHIR.
Regional dataBrussels network (RSB) documents in KMEHR format, cached and converted locally; used only for patients who consented, according to the hospital.
HostingModel, data and indexes inside the hospital network, with no internet access. Exception: internal procedures from SharePoint are indexed on a private Azure tenant. No data kept outside the session.
Access and auditEpic role-based permissions and audit logs apply; data access is ephemeral and auditable.
EthicsThe ethics committee classed the project as a study of practice, not a clinical investigation. The medical direction approved production use.
Data protectionData Protection Officer consulted; DPIA completed before deployment, confirming that no patient data leaves the hospital.
Medical deviceDeclared to the Belgian medicines agency (AFMPS/FAGG) as an in-house device, class IIa, under EU MDR article 5(5). This exemption covers use at Saint-Luc only.
EU AI ActVoluntary alignment with high-risk requirements: intended-use and technical documentation, versioning, user training, post-deployment monitoring. No formal conformity claimed.
Clinician involvementPhysician workshops to choose use cases; a network of "EHR champions" from several specialties involved from design to testing; a review session before go-live.
Model updatesEach new model is tested on benchmarks and standard tasks, then used by the champions for a set period before release to all users.
MonitoringIn-app rating with reasons, feedback reviewed monthly, and a dashboard of usage, latency and errors.

04Measured results

Adoption was high, but clinical outcomes, accuracy and time savings were deliberately not measured.

Pilot (one month, 28 volunteer physicians): 18 used it daily and 5 stopped after trying it; 482 conversations and 1,630 messages.

What the first request asked forShare of conversations
Summarising the chart29.5%
Finding specific information29.2%
Differential diagnosis25.1%
Drafting note sections15.1%

Feedback: users rated only 47 of 815 answers (5.8%): 25 positive, 22 negative. Negative reasons were mostly omissions (for example pathology reports that were not indexed), misunderstandings (for example one item of a bleeding-risk score) and one reported hallucination, which turned out to be a true but undocumented clinical consideration.

Rollout: 1,028 users and 14,910 conversations over five months, with more than half of clinicians using it at least weekly.

Not measured: time saved, accuracy and error rates, effect on patients. The "less than a minute" record review reported in the press is not backed by a published measurement.

05Lessons learned

Clinicians used the assistant to find and gather information far more than to make decisions; the authors describe it as perceived "as a documentation aid, rather than a support for clinical reasoning".

What worked, according to the team

  • Launching from inside Epic with a familiar chat interface: no extra login, little training.
  • Letting physicians choose the use cases from the start, and involving EHR champions throughout.
  • Showing sources with every answer, so clinicians can check them.
  • Running everything on site, which simplified the data protection case.

What did not, or not yet

  • Omissions came from data plumbing (for example pathology not indexed in FHIR) more than from the model.
  • Explicit feedback was rare, so quality monitoring also needs implicit signals.
  • Early technical issues: a missing launch icon for some patients, failed document retrieval, slow answers.
  • Volunteer pilot users, a single site and no outcome data limit what can be concluded.

Cost and effort: not published (team size, build time, hardware and running costs).

↗Sources

Last updated 20 November 2026.

Deployed AI in your hospital?Share your experience and we will document it with you.
Share a use case